{"title":"Vision Testing Equipment","description":"","products":[{"product_id":"handheld-fundus-camera-retinal-imaging","title":"Handheld Fundus Camera - Retinal Imaging","description":"\u003ch2 data-section-id=\"rtra5r\" data-start=\"156\" data-end=\"175\"\u003eProduct Details\u003c\/h2\u003e\n\u003cp data-start=\"176\" data-end=\"681\"\u003eThe \u003cstrong data-start=\"180\" data-end=\"230\"\u003eRemidio Handheld Fundus Camera (FOP-NM Series)\u003c\/strong\u003e is a portable, non-mydriatic retinal imaging system designed to deliver high-quality fundus images quickly and efficiently in virtually any clinical setting. Built for point-of-care use, this handheld device allows clinicians to capture clear retinal images in under a minute—without the need for pupil dilation or high-intensity flash—making the process more comfortable for patients and faster for providers. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"683\" data-end=\"1050\"\u003eDesigned with a mobile-first approach, the system is ideal for primary care, ophthalmology, emergency departments, and remote screening programs. Its intuitive operation, including guided alignment and auto-capture functionality, allows even non-specialist users to obtain consistent, high-quality images with minimal training. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1052\" data-end=\"1315\"\u003eWith seamless connectivity to EMR and PACS systems, the Remidio fundus camera supports efficient workflows, enabling clinicians to store, share, and review images for remote consultation and tele-ophthalmology applications.\u003c\/p\u003e\n\u003cp data-start=\"1052\" data-end=\"1315\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/26ZDN0BrJGM?si=Bw7OAGkb03XxxfC7\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr data-start=\"1317\" data-end=\"1320\"\u003e\n\u003ch2 data-section-id=\"omktqu\" data-start=\"1322\" data-end=\"1338\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1339\" data-end=\"2073\"\u003e\n\u003cli data-section-id=\"xxu4qq\" data-start=\"1339\" data-end=\"1426\"\u003e\n\u003cstrong data-start=\"1341\" data-end=\"1374\"\u003eNon-mydriatic retinal imaging\u003c\/strong\u003e with no dilation or high-intensity flash required\u003c\/li\u003e\n\u003cli data-section-id=\"c8sq44\" data-start=\"1427\" data-end=\"1509\"\u003e\n\u003cstrong data-start=\"1429\" data-end=\"1479\"\u003eHigh-quality image capture in under one minute\u003c\/strong\u003e for fast clinical workflows\u003c\/li\u003e\n\u003cli data-section-id=\"j6a0v8\" data-start=\"1510\" data-end=\"1596\"\u003e\n\u003cstrong data-start=\"1512\" data-end=\"1549\"\u003eAuto-capture and guided alignment\u003c\/strong\u003e for consistent results with minimal training\u003c\/li\u003e\n\u003cli data-section-id=\"gc56pe\" data-start=\"1597\" data-end=\"1681\"\u003e\n\u003cstrong data-start=\"1599\" data-end=\"1649\"\u003eWide-field retinal imaging (40° field of view)\u003c\/strong\u003e for comprehensive assessments\u003c\/li\u003e\n\u003cli data-section-id=\"ehqgrl\" data-start=\"1682\" data-end=\"1748\"\u003e\n\u003cstrong data-start=\"1684\" data-end=\"1718\"\u003eEight internal fixation points\u003c\/strong\u003e for improved image coverage\u003c\/li\u003e\n\u003cli data-section-id=\"1j6uvm7\" data-start=\"1749\" data-end=\"1821\"\u003e\n\u003cstrong data-start=\"1751\" data-end=\"1780\"\u003ePortable, handheld design\u003c\/strong\u003e for point-of-care and mobile screening\u003c\/li\u003e\n\u003cli data-section-id=\"2lm3mo\" data-start=\"1822\" data-end=\"1888\"\u003e\n\u003cstrong data-start=\"1824\" data-end=\"1857\"\u003eSeamless EMR\/PACS integration\u003c\/strong\u003e for data storage and sharing\u003c\/li\u003e\n\u003cli data-section-id=\"r2jxfe\" data-start=\"1889\" data-end=\"1961\"\u003e\n\u003cstrong data-start=\"1891\" data-end=\"1924\"\u003eHIPAA-compliant data security\u003c\/strong\u003e for patient information protection\u003c\/li\u003e\n\u003cli data-section-id=\"dfhw18\" data-start=\"1962\" data-end=\"2073\"\u003e\n\u003cstrong data-start=\"1964\" data-end=\"1997\"\u003eInfrared and LED illumination\u003c\/strong\u003e for clear, patient-friendly imaging \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1rjnwwu\" data-start=\"2080\" data-end=\"2099\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"2136\" data-end=\"2378\"\u003e\n\u003cli data-section-id=\"1uinlz5\" data-start=\"2136\" data-end=\"2177\"\u003eRemidio Handheld Fundus Camera device\u003c\/li\u003e\n\u003cli data-section-id=\"rsi57l\" data-start=\"2178\" data-end=\"2218\"\u003eIntegrated imaging system and optics\u003c\/li\u003e\n\u003cli data-section-id=\"wn0x47\" data-start=\"2219\" data-end=\"2250\"\u003eRechargeable battery system\u003c\/li\u003e\n\u003cli data-section-id=\"1rc2ttd\" data-start=\"2251\" data-end=\"2275\"\u003eCharging accessories\u003c\/li\u003e\n\u003cli data-section-id=\"wlr3aw\" data-start=\"2276\" data-end=\"2310\"\u003eUser interface\/software access\u003c\/li\u003e\n\u003cli data-section-id=\"uck10\" data-start=\"2311\" data-end=\"2344\"\u003eCarrying case (if applicable)\u003c\/li\u003e\n\u003cli data-section-id=\"1rtrztm\" data-start=\"2345\" data-end=\"2378\"\u003eUser manual and documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2380\" data-end=\"2383\"\u003e\n\u003ch2 data-section-id=\"1o8as2a\" data-start=\"2385\" data-end=\"2397\"\u003eWarranty\u003c\/h2\u003e\n\u003ch3 data-start=\"2398\" data-end=\"2637\"\u003e\u003cstrong data-start=\"2444\" data-end=\"2517\"\u003eWhat happens if it breaks?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2398\" data-end=\"2637\"\u003e\u003cstrong data-start=\"2444\" data-end=\"2517\"\u003eManufacturer’s warranty: \u003c\/strong\u003eCovers defects in materials and workmanship. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMorningside Medical Equipment General Refund Policy:\u003c\/strong\u003e There is a 30-day Return Policy (from the date of delivery) for all supplies and products purchased through our online store. These items must be unopened, unused, and in the original manufacturer packaging. Unfortunately, no returns will be accepted if used or damaged, or after the 30-day period. Customers are responsible for all shipping charges associated with the return. Initial shipping charges will not be refunded, and a 15%-20% restocking fee could be applied depending on the product.\u003c\/p\u003e\n\u003cp\u003eSee our terms and conditions for more information: \u003ca href=\"http:\/\/www.morningsidemedicalequipment.com\/terms-and-conditions\"\u003ewww.morningsidemedicalequipment.com\/terms-and-conditions\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr data-start=\"2639\" data-end=\"2642\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eImaging\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImaging Type\u003c\/td\u003e\n\u003ctd\u003eNon-mydriatic retinal imaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e40°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapture Modes\u003c\/td\u003e\n\u003ctd\u003eManual and auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixation Targets\u003c\/td\u003e\n\u003ctd\u003e8 internal fixation points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eInfrared and cool white LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eSystem \u0026amp; Performance\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Capture Time\u003c\/td\u003e\n\u003ctd\u003eUnder 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorkflow Integration\u003c\/td\u003e\n\u003ctd\u003eEMR \/ PACS compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Security\u003c\/td\u003e\n\u003ctd\u003eHIPAA-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~2.5 lbs (1.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.66\" × 11.18\" × 8.90\" (93 × 284 × 226 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eUp to ~7 hours continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Remido","offers":[{"title":"Default Title","offer_id":48100900045054,"sku":null,"price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/DiabeticRetinopathyCamera.png?v=1776780520"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/collections\/Icon-08.png?v=1767257830","url":"https:\/\/www.morningsidemedicalequipment.com\/collections\/vision-testingequipment.oembed","provider":"Morningside Medical Equipment","version":"1.0","type":"link"}