{"product_id":"chattanooga-single-laser-diode-820-nm-300-mw","title":"Single Laser Diode, 820 nm, 300 mW","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\u003cp\u003eThe Chattanooga Single Laser Diode, 820 nm, 300 mW (SKU 27805) is a single-diode laser applicator delivering 300 mW of optical power at a 820 nm wavelength. It is an interchangeable applicator for Chattanooga's Vectra Genisys Transport Laser and Vectra Neo Laser Therapy Module, carrying Electronic Signature Recognition so the host device auto-detects the applicator for plug-and-use operation. The host system supports continuous and pulsed treatment modes with real-time dosage feedback in joules or joules\/cm, plus a selectable library of clinical-indication and user-defined treatment protocols. Use of this product is restricted to licensed health professionals.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSingle laser diode emitting at 820 nm — a near-infrared wavelength\u003c\/li\u003e\n\u003cli\u003e300 mW optical power output for focused, point-of-care treatment\u003c\/li\u003e\n\u003cli\u003ePlug-and-use Electronic Signature Recognition — the Vectra Genisys or Vectra Neo host auto-detects the applicator\u003c\/li\u003e\n\u003cli\u003eContinuous and pulsed treatment modes with real-time dosage feedback in joules or joules\/cm\u003c\/li\u003e\n\u003cli\u003eLaser therapy can be started, paused and adjusted directly from the applicator hand-piece\u003c\/li\u003e\n\u003cli\u003eCompatible with the Vectra Genisys Transport Laser and the Vectra Neo Laser Therapy Module\u003c\/li\u003e\n\u003cli\u003eOne of eight interchangeable laser diode and cluster applicators in the Chattanooga family (100 mW to 1440 mW)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhat You Get\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eLaser applicator hand-piece\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eWarranty\u003c\/h2\u003e\u003ch3\u003e\u003cstrong\u003eWhat happens if it breaks?\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eManufacturer's warranty: \u003c\/strong\u003eChattanooga warranty terms apply. Please refer to the manufacturer's documentation included with the product.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMorningside Medical Equipment General Refund Policy:\u003c\/strong\u003e There is a 30-day Return Policy (from the date of delivery) for all supplies and products purchased through our online store. These items must be unopened, unused, and in the original manufacturer packaging. Unfortunately, no returns will be accepted if used or damaged, or after the 30-day period. Customers are responsible for all shipping charges associated with the return. Initial shipping charges will not be refunded, and a 15%-20% restocking fee could be applied depending on the product.\u003c\/p\u003e\u003cp\u003eSee our terms and conditions for more information: \u003ca href=\"https:\/\/www.morningsidemedicalequipment.com\/terms-and-conditions\"\u003ewww.morningsidemedicalequipment.com\/terms-and-conditions\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e820 nm (near-infrared)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power Output\u003c\/td\u003e\n\u003ctd\u003e300 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Configuration\u003c\/td\u003e\n\u003ctd\u003e1 x 300 mW laser diode at 820 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator Type\u003c\/td\u003e\n\u003ctd\u003eSingle laser diode probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVectra Genisys Transport Laser; Vectra Neo Laser Therapy Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment Modes\u003c\/td\u003e\n\u003ctd\u003eContinuous and pulsed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosage Display\u003c\/td\u003e\n\u003ctd\u003eJoules or joules\/cm, real-time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator Identification\u003c\/td\u003e\n\u003ctd\u003eElectronic Signature Recognition (auto-detect on host device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eRestricted to licensed health professionals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Chattanooga","offers":[{"title":"Default Title","offer_id":48269027999998,"sku":"27805","price":2639.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/API_27805_Laser_Probes_Jfeh_a317dcb1-9819-4f14-8752-21cc2be83fe4.jpg?v=1779988875","url":"https:\/\/www.morningsidemedicalequipment.com\/products\/chattanooga-single-laser-diode-820-nm-300-mw","provider":"Morningside Medical Equipment","version":"1.0","type":"link"}