{"product_id":"newman-medical-simpleabi-cuff-link-system","title":"Newman Medical simpleABI Automated Cuff-Link System","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cp\u003eThe simpleABI Automated Cuff-Link System is a \u003cstrong\u003ePC-based vascular testing workstation for diagnosing peripheral artery disease.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses continuous-wave Doppler ultrasound — the AHA\/ACC gold standard for PAD diagnosis — together with pulse volume recording waveforms, and automates cuff selection, inflation and deflation so results stay consistent from one operator to the next.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003esystem runs multiple exam types on one workstation\u003c\/strong\u003e, from ABI-Q PVR screening through multi level Doppler ABI to exercise and treadmill stress testing. Choose the configuration that matches your practice.\u003c\/p\u003e\n\u003cp\u003eWith the simpleABI Automated Cuff-Link System, accurate full-page reports are quickly produced with the necessary documentation for reimbursement. The exam is made easy by following the report being generated on the computer screen, eliminating the need for memorizing complex menus or protocols. Since the system automatically generates the report, there is no need for secondary downloading steps to store, print or share the results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose your configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTwo choices build your system: \u003cstrong\u003estudy level\u003c\/strong\u003e and \u003cstrong\u003eexercise protocol\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eStudy level\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSingle level studies\u003c\/strong\u003e — for diagnosing the presence of obstruction and confirming a diagnosis of PAD. Runs on a four-port cuff selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSingle and multi level studies\u003c\/strong\u003e — adds segmental studies for determining \u003cem\u003ewhere\u003c\/em\u003e the obstruction sits (aortoiliac, femoral, popliteal, tibial), which guides treatment planning, interventional decisions and follow-up after revascularization. It is fully aligned with AHA\/ACC guidelines. Runs on an eight port cuff selector, so several cuffs stay connected at once and nobody has to swap lines mid-exam.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eExercise exams\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAround 30 percent of patients with symptoms of PAD test normal at rest but abnormal after exercise, so an exercise study catches disease a resting study misses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Maneuvers\u003c\/strong\u003e — a post-exercise ABI performed table-side, with no gym or exercise equipment needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Maneuvers and Stress Testing\u003c\/strong\u003e \u003cem\u003e(treadmill not included)\u003c\/em\u003e — while resting and post-exercise ABI confirm the presence of PAD, the added stress test exam \u003cstrong\u003equantifies how much the disease is limiting the patient.\u003c\/strong\u003e Maximum walking time, the point at which claudication begins, and the time required for pressure to recover after stopping all provide objective functional data that resting exams cannot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClinical applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAD diagnosis and confirmation, and baseline vascular assessment in at-risk patients\u003c\/li\u003e\n\u003cli\u003eDiabetic patient vascular evaluation, including calcified and incompressible arteries\u003c\/li\u003e\n\u003cli\u003eWound care and limb preservation programs\u003c\/li\u003e\n\u003cli\u003ePrimary care and podiatry screening, with rapid screening and Doppler confirmation on one device\u003c\/li\u003e\n\u003cli\u003eSymptomatic patients and claudication evaluation — \u003cem\u003eon stress testing configurations\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003ePre-interventional planning and post-procedural follow-up — \u003cem\u003eon multi level configurations\u003c\/em\u003e, where localizing the affected segment is what guides the decision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoppler and probes\u003c\/strong\u003e — the Doppler is built into the control unit and has the sensitivity and audio response to let you hear blood flow sounds quickly and clearly, through a high-fidelity speaker with a smooth, rich response across the whole range of Doppler sounds.\u003c\/p\u003e\n\u003cp\u003eAutomated Cuff-Link systems \u003cstrong\u003einclude an 8 MHz probe and an SPPG probe\u003c\/strong\u003e. All probes are interchangeable and work on every Cuff-Link system, with a smooth contour that is comfortable to hold, comfortable for the patient and easy to clean.\u003c\/p\u003e\n\u003cp\u003eAdditional probes available:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 MHz probe\u003c\/strong\u003e — deep penetration for the femoral, popliteal and brachial arteries and for deep veins. Available separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteadyDop probes\u003c\/strong\u003e — wide-angle versions of the 5 MHz and 8 MHz probes, which makes vessels easier to locate. Available separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless EMR integration\u003c\/strong\u003e — reports can be printed on any standard printer or saved as PDF\/TIFF files for easy attachment to EMR patient records.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterested in DICOM connectivity?\u003c\/strong\u003e Call us at 800-675-1202 or email info@morningsidemedical.com for more information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories and supplies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplacement cuffs, Cuff-Link tubing, ultrasound gel, carry bags and additional probes are listed in our \u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e\u003ca href=\"\/collections\/abi-supplies\" style=\"color: rgb(43, 0, 255); text-decoration: underline;\"\u003eABI supplies collection\u003c\/a\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Reports\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable exams by study level configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100.061%; height: 1234.41px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 97.9688px;\"\u003e\n\u003cth style=\"width: 14.4529%; height: 97.9688px;\"\u003eSample report\u003c\/th\u003e\n\u003cth style=\"width: 59.7209%; height: 97.9688px;\"\u003eExam description\u003c\/th\u003e\n\u003cth style=\"width: 10.135%; height: 97.9688px;\"\u003eSingle level studies\u003c\/th\u003e\n\u003cth style=\"width: 11.154%; height: 97.9688px;\"\u003eSingle and multi level studies\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 117.562px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 117.562px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_Q_Report-NM0133.pdf?v=1789738588\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eRapid ABI-Q exam\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 117.562px;\"\u003ePneumatic cuffs are placed on both ankles. The system records pulse volume recordings from each ankle simultaneously, which takes one to two minutes. A proprietary algorithm analyzes waveform morphology and outputs a clear PAD present \/ absent assessment.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 117.562px;\"\u003e✓\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 117.562px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 156.75px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 156.75px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_ABI_Report-NM0024.pdf?v=1789739257\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eABI: \u003c\/span\u003e\u003c\/a\u003ethe gold standard for PAD\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 156.75px;\"\u003eFour cuffs are placed bilaterally on both arms and both ankles, with the patient supine and rested. The system inflates all cuffs and captures systolic pressures and PVR waveforms at each site. Software calculates bilateral ABI ratios and generates a full-page report with waveforms, pressures and interpretation guidance. A ratio below 0.90 is diagnostic for PAD.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 137.156px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 137.156px;\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_ABI_with_Toe_Report-NM0029.pdf?v=1789739257\" style=\"color: rgb(43, 0, 255); text-decoration: underline;\" target=\"_blank\"\u003eABI with Toe\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 137.156px;\"\u003eArm and ankle pressures are captured first. If ankle pressure exceeds 200 mmHg or the ABI exceeds 1.40, TBI is indicated. Small digit cuffs are placed on both great toes and the PPG photoplethysmography probe captures toe arterial pulses. Software calculates the toe brachial ratio and generates a combined ABI and TBI report with waveforms and interpretation.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 137.156px;\"\u003e✓\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 137.156px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 97.9688px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 97.9688px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_SeatedABI_InstructionsNM0102.pdf?v=1789743544\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eSeated ABI\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 97.9688px;\"\u003eAn ABI exam is generally done with the patient supine. Where it is difficult for the patient to lie down, the exam can be taken with the arm and ankle cuffs at different heights. A guide is supplied for correcting the pressure difference on a seated ABI.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 97.9688px;\"\u003e✓\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 97.9688px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 156.75px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 156.75px;\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_3-cuff_Segmental_Report-NM0050.pdf?v=1789739257\" style=\"color: rgb(43, 0, 255); text-decoration: underline;\" target=\"_blank\"\u003eThree cuff Segmental\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 156.75px;\"\u003eThree cuffs are placed bilaterally at the thigh, calf and ankle, with the Doppler probe positioned at the ankle (posterior tibial). Each cuff level is inflated and deflated in sequence, and pressures and PVR waveforms are captured at all three levels. Software calculates the pressure drop between levels; a gradient greater than 20 mmHg between adjacent segments indicates occlusion at that level.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 156.75px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 156.75px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 156.75px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_3-cuff_w-Toe_Segmental_Report-NM0076.pdf?v=1789739257\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eThree cuff Segmental with Toe\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 156.75px;\"\u003eThe three cuff segmental study with digit cuffs and the PPG probe added at both great toes. Pressures and PVR waveforms are captured at all three segmental levels and toe pressures are recorded via PPG photoplethysmography. The report combines three-level pressure gradient analysis with TBI, for patients whose ankle vessels are calcified and an ankle pressure cannot be obtained.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 156.75px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 156.75px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 156.75px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_4-cuff_Segmental_Report-NM0027.pdf?v=1789739257\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eFour cuff Segmental\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 156.75px;\"\u003eFour cuffs are placed bilaterally at the high thigh, low thigh, calf and ankle, with the Doppler probe at the posterior tibial artery. Each cuff is inflated and deflated in sequence and systolic pressure and PVR waveform are captured at all four levels on both sides. Software maps the pressure gradient across all four segments, showing which level carries hemodynamically significant disease.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 156.75px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 156.75px;\"\u003e\n\u003ctd style=\"width: 14.4529%; height: 156.75px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_4-cuff_w-Toe_Segmental_Report-NM0115.pdf?v=1789739257\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eFour cuff Segmental with Toe\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.7209%; height: 156.75px;\"\u003eFour bilateral segmental cuffs at the high thigh, low thigh, calf and ankle, with digit cuffs and the PPG probe at both great toes. Pressures and PVR waveforms are captured at all four segmental levels and toe pressures are recorded via PPG photoplethysmography. The report combines four-level pressure gradient analysis with TBI, delivering a complete picture from proximal to distal.\u003c\/td\u003e\n\u003ctd style=\"width: 10.135%; height: 156.75px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 11.154%; height: 156.75px;\"\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e✓ available · — not available on that configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable exams by exercise configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eExam\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eExam description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Maneuvers\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Maneuvers and Stress Testing\u003cbr\u003e\u003cem\u003e(treadmill not included)\u003c\/em\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/MAN-0017-B-SIMPLEABI_CUFF-LINK_QUICK_START_6-ABI_WITH_EXERCISE.pdf?v=1789742037\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eABI with exercise\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eA standard resting ABI is captured with all cuffs in place, serving as the pre-exercise baseline. The patient then performs provocative functional maneuvers such as dorsiflexion, heel raises or hall walking, until claudication onset or a set time limit. No treadmill is required. Cuffs remain in place and immediate post-exercise readings are taken and tracked over recovery, documenting the pressure drop and the recovery time.\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/simpleABI_sample_ABI_Stress-Treadmill_Report-NM0077.pdf?v=1789739257\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eABI stress treadmill\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eA full bilateral resting ABI with PVR waveforms is captured before the patient begins walking, establishing the pre-stress baseline. The patient walks at a defined speed and incline while staff record maximum walking time, onset of claudication symptoms and the reason for stopping. Post-treadmill ABI is captured at 1, 3, 5 and 10 minutes after stopping, and the pressure recovery curve and recovery time are documented in the full report.\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e✓ available · — not available on that configuration.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous-wave Doppler ankle brachial index with toe brachial index\u003c\/li\u003e\n\u003cli\u003eAutomated cuff selection, inflation and deflation through Cuff-Link technology\u003c\/li\u003e\n\u003cli\u003eIntegrated rapid PVR screening exam for Doppler-free assessment of calcified or incompressible arteries\u003c\/li\u003e\n\u003cli\u003eConsistent, repeatable results across different operators\u003c\/li\u003e\n\u003cli\u003eReport builds on screen during the exam — no strip-chart paper, no secondary data transfer\u003c\/li\u003e\n\u003cli\u003eShort staff training and re-training time — no menus or protocols to memorize\u003c\/li\u003e\n\u003cli\u003eDrop-down ICD-10 codes and interpretation of results on every report\u003c\/li\u003e\n\u003cli\u003eSegmental configurations localize disease to a limb segment rather than only detecting it\u003c\/li\u003e\n\u003cli\u003eSeated ABI protocol on every configuration for patients who cannot lie flat\u003c\/li\u003e\n\u003cli\u003eCompact workstation footprint designed for in-room use\u003c\/li\u003e\n\u003cli\u003eDesigned and manufactured in the United States, near Denver, Colorado\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat You Get\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe Cuff-Link main control\u003c\/strong\u003e — an integrated speed machine. One box holds the cuff selector, interchangeable Doppler probes, pressure sensors, the pump and the control software. That integration is what makes the exam faster and easier to perform, and what takes the costly errors out of it.\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle level studies:\u003c\/strong\u003e four port cuff selector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle and multi level studies:\u003c\/strong\u003e eight port cuff selector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe Cuff-Link remote\u003c\/strong\u003e — steps the operator through the exam with push-button simplicity.\n\u003cul\u003e\n\u003cli\u003eMove easily from one measurement site to the next\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read display of the current cuff pressure\u003c\/li\u003e\n\u003cli\u003ePush-button inflation\u003c\/li\u003e\n\u003cli\u003eAutomated cuff deflation, which is what keeps pressures accurate\u003c\/li\u003e\n\u003cli\u003eOne-button waveform creation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoppler and probes\u003c\/strong\u003e — the Doppler is built into the control unit, and all probes are interchangeable and work on every Cuff-Link system, with a smooth contour that is comfortable to hold, comfortable for the patient and easy to clean.\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 MHz probe\u003c\/strong\u003e — especially sensitive to vessels near the surface: the radial, posterior tibial and dorsalis pedis arteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPPG probe\u003c\/strong\u003e — produces photoplethysmography waveforms during toe brachial index studies, which is what you need when the ankle arteries are calcified or occluded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic probe holder\u003c\/strong\u003e — cradles the probe without cracking or breaking, with an open design that does not gather dirt, gel or germs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEZ-Clean Vasocuffs\u003c\/strong\u003e — washable soft material over a non-latex bladder, long enough to completely encircle the limb.\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle level studies:\u003c\/strong\u003e six cuffs — two 10 cm, two 12 cm and two 1.9 cm disposable digit cuffs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle and multi level studies:\u003c\/strong\u003e ten cuffs — two 10 cm, four 12 cm, two 12 cm long and two 1.9 cm disposable digit cuffs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight-adjustable roll stand\u003c\/strong\u003e — wide five-legged anti-tip base, mounting plate for the computer and control unit, hooks for the hoses and a basket for cuffs and gel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaptop with simpleABI software\u003c\/strong\u003e — no separate step to download the data.\n\u003cul\u003e\n\u003cli\u003eIndices are calculated automatically, which takes a whole class of error out of the exam\u003c\/li\u003e\n\u003cli\u003eEvery exam is stored automatically with a timestamp\u003c\/li\u003e\n\u003cli\u003eYour practice logo and contact information print on the report\u003c\/li\u003e\n\u003cli\u003eYour physicians, operators and interpreters sit on editable drop-down menus\u003c\/li\u003e\n\u003cli\u003eDrop-down ICD-10 codes\u003c\/li\u003e\n\u003cli\u003eInterpretation of results is shown on the report\u003c\/li\u003e\n\u003cli\u003eReports save in the format you need: PDF, TIFF, CSV, BMP or JPG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUser manual and training\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eA treadmill is not included with any configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat happens if it breaks?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer’s warranty: \u003c\/strong\u003eEvery simpleABI system carries a \u003cstrong\u003ecomprehensive 2-year warranty\u003c\/strong\u003e covering all parts and labor, including the Cuff-Link control unit, probes and cords.\u003c\/p\u003e\n\u003cp\u003eNewman Medical also extends a 60-day satisfaction guarantee.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMorningside Medical Equipment General Refund Policy:\u003c\/strong\u003e There is a 30-day Return Policy (from the date of delivery) for all supplies and products purchased through our online store. These items must be unopened, unused, and in the original manufacturer packaging. Unfortunately, no returns will be accepted if used or damaged, or after the 30-day period. Customers are responsible for all shipping charges associated with the return. Initial shipping charges will not be refunded, and a 15%-20% restocking fee could be applied depending on the product.\u003c\/p\u003e\n\u003cp\u003eSee our terms and conditions for more information: \u003ca href=\"http:\/\/www.morningsidemedicalequipment.com\/terms-and-conditions\"\u003ewww.morningsidemedicalequipment.com\/terms-and-conditions\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight, system on stand\u003c\/td\u003e\n\u003ctd\u003e107 cm (42 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, system on stand\u003c\/td\u003e\n\u003ctd\u003e5.5 kg (12 pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping carton\u003c\/td\u003e\n\u003ctd\u003e20 x 20 x 26 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e10 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e30% to 75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eTransport and storage\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 °C (-4 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel of protection\u003c\/td\u003e\n\u003ctd\u003eType B applied part, Class II equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign standards\u003c\/td\u003e\n\u003ctd\u003eIEC 60601-1, IEC 60601-2, IEC 60601-2-37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of manufacture\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Newman Medical","offers":[{"title":"Single level studies \/ Functional Maneuvers","offer_id":48965537333502,"sku":"ABI-400CL","price":5935.55,"currency_code":"USD","in_stock":true},{"title":"Single level studies \/ Functional Maneuvers and Stress Testing","offer_id":48965537366270,"sku":"ABI-450CL","price":8340.25,"currency_code":"USD","in_stock":true},{"title":"Single and multi level studies \/ Functional Maneuvers","offer_id":48965537399038,"sku":"ABI-500CL","price":8764.61,"currency_code":"USD","in_stock":true},{"title":"Single and multi level studies \/ Functional Maneuvers and Stress Testing","offer_id":48965537431806,"sku":"ABI-600CL","price":11169.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/ABI-600CL_dccb8862-0aca-4c0b-bf7b-cc9239bc3549.png?v=1789499560","url":"https:\/\/www.morningsidemedicalequipment.com\/products\/newman-medical-simpleabi-cuff-link-system","provider":"Morningside Medical Equipment","version":"1.0","type":"link"}