{"product_id":"schiller-medilog-ar-holter-recorder-no-software-included","title":"Schiller Medilog AR Holter Recorder - No Software Included","description":"\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eM\u003c\/strong\u003e\u003cstrong\u003eedilog AR Holter monitor\u003c\/strong\u003e is a monitor-only option for practices that already use \u003cstrong\u003eMedilog DARWIN2 Office Software\u003c\/strong\u003e. It does not include analysis software. Your existing DARWIN2 activation code can be used with additional medilog AR monitors because the license is tied to the computer, not the individual monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdding monitors or replacing an existing unit?\u003c\/strong\u003e This is the right product if your practice already runs DARWIN2 and you want to monitor more patients at the same time, add monitors to an existing setup, or replace a Medilog AR monitor already in service.\u003c\/p\u003e\n\u003cp\u003eThe Medilog AR monitor supports \u003cstrong\u003econtinuous recording for up to 14 days without recharging\u003c\/strong\u003e, giving your practice one Holter monitor that can be used for routine 24- or 48-hour studies as well as extended 7- or 14-day recordings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose your lead configuration.\u003c\/strong\u003e The Medilog AR Holter monitor is available with either a \u003cstrong\u003e5-lead or 7-lead patient cable\u003c\/strong\u003e and automatically detects which cable is connected. Choose \u003cstrong\u003e5-lead\u003c\/strong\u003e for routine 3-channel Holter studies or \u003cstrong\u003e7-lead\u003c\/strong\u003e for an additional chest lead and more diagnostic detail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdding your first Medilog AR Holter monitor?\u003c\/strong\u003e If this is your first Holter setup, purchase the \u003ca href=\"\/products\/schiller-medilogar-holter-system\" style=\"color: #1285bc; text-decoration: underline;\"\u003eSchiller Medilog AR Holter System\u003c\/a\u003e instead. It includes this same monitor along with DARWIN2 Office software and one activation code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePurchasing monitors with a new system?\u003c\/strong\u003e Add additional Holter monitors in the same lead configuration as your system and \u003cstrong\u003eget $250.00 off at checkout\u003c\/strong\u003e when purchasing them at the same time as the \u003ca href=\"\/products\/schiller-medilogar-holter-system\" style=\"color: #1285bc; text-decoration: underline;\"\u003eSchiller Medilog AR Holter System\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed DARWIN2 Software on another computer?\u003c\/strong\u003e Each workstation used to upload recordings and analyze or generate reports requires its own activation code. Additional activation codes are available from the \u003ca href=\"\/products\/schiller-medilog-darwin2-office-holter-analysis-software\" style=\"color: #1285bc; text-decoration: underline;\"\u003eSchiller Medilog DARWIN2 Office Holter Analysis Software\u003c\/a\u003e page.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 14 days of continuous recording without battery recharging\u003c\/li\u003e\n\u003cli\u003eOne AAA battery with a flexible dual-battery concept for recordings up to 14 days\u003c\/li\u003e\n\u003cli\u003eOne Holter monitor for 24-hour, 48-hour, 7-day, or up to 14-day recordings\u003c\/li\u003e\n\u003cli\u003e32,000 Hz sampling rate\u003c\/li\u003e\n\u003cli\u003e3-channel EKG preview and signal quality check\u003c\/li\u003e\n\u003cli\u003eTrue signal quality check with amplitude indication\u003c\/li\u003e\n\u003cli\u003eAutomatic detection of 5- or 7-lead patient cable\u003c\/li\u003e\n\u003cli\u003eArtifact suppression and motion detection\u003c\/li\u003e\n\u003cli\u003e3D motion detection to help suppress artifacts and speed evaluation\u003c\/li\u003e\n\u003cli\u003eQT\/ST analysis\u003c\/li\u003e\n\u003cli\u003eAdult and pediatric patient support\u003c\/li\u003e\n\u003cli\u003eSmall, lightweight monitor with 128 x 64 px OLED display\u003c\/li\u003e\n\u003cli\u003eShock- and splash-resistant design (IP22)\u003c\/li\u003e\n\u003cli\u003eSD or USB data download\u003c\/li\u003e\n\u003cli\u003eWorks with an existing medilog DARWIN2 Office workstation under its activation code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat You Get\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003emedilog AR Holter monitor\u003c\/li\u003e\n\u003cli\u003eProtective case with belt clip\u003c\/li\u003e\n\u003cli\u003eMicro SD card\u003c\/li\u003e\n\u003cli\u003eMicro USB cable\u003c\/li\u003e\n\u003cli\u003eNeck belt\u003c\/li\u003e\n\u003cli\u003e5-lead or 7-lead patient cable, matching your selected configuration\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003ch3\u003eWhat happens if it breaks?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer's warranty:\u003c\/strong\u003e Covered by SCHILLER's standard manufacturer warranty. Contact us for warranty term and coverage details for your configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMorningside Medical Equipment General Refund Policy:\u003c\/strong\u003e There is a 30-day Return Policy (from the date of delivery) for all supplies and products purchased through our online store. These items must be unopened, unused, and in the original manufacturer packaging. Unfortunately, no returns will be accepted if used or damaged, or after the 30-day period. Customers are responsible for all shipping charges associated with the return. Initial shipping charges will not be refunded, and a 15%-20% restocking fee could be applied depending on the product.\u003c\/p\u003e\n\u003cp\u003eSee our terms and conditions for more information: \u003ca href=\"http:\/\/www.morningsidemedicalequipment.com\/terms-and-conditions\" style=\"color: #1285bc; text-decoration: underline;\"\u003ewww.morningsidemedicalequipment.com\/terms-and-conditions\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuration\u003c\/td\u003e\n\u003ctd\u003e24 hours, 48 hours, 7 days, or up to 14 days on one Holter monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e3-channel EKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e32,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient cable\u003c\/td\u003e\n\u003ctd\u003e5- or 7-lead, automatically detected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatients\u003c\/td\u003e\n\u003ctd\u003eAdult and pediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eSignal Quality and Analysis\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreview\u003c\/td\u003e\n\u003ctd\u003e3-channel EKG preview with signal quality check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality check\u003c\/td\u003e\n\u003ctd\u003eTrue signal quality check with amplitude indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArtifacts\u003c\/td\u003e\n\u003ctd\u003eArtifact suppression with 3D motion detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis\u003c\/td\u003e\n\u003ctd\u003eQT\/ST analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis software\u003c\/td\u003e\n\u003ctd\u003eNot included; medilog DARWIN2 Office required, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLicensing\u003c\/td\u003e\n\u003ctd\u003eRuns under the activation code on your existing DARWIN2 workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eHardware\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eOne AAA battery, flexible dual-battery concept\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eOLED, 128 x 64 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShock- and splash-resistant, IP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData download\u003c\/td\u003e\n\u003ctd\u003eSD or USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003eServices\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation and training\u003c\/td\u003e\n\u003ctd\u003eNot included; available on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schiller","offers":[{"title":"5 - lead","offer_id":48914345197822,"sku":"1A.306010-5L","price":3227.4,"currency_code":"USD","in_stock":true},{"title":"7 - lead","offer_id":48914345230590,"sku":"1A.306010-7L","price":3425.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/8686\/8222\/files\/medilog-ar-main.webp?v=1785190881","url":"https:\/\/www.morningsidemedicalequipment.com\/products\/schiller-medilog-ar-holter-recorder-no-software-included","provider":"Morningside Medical Equipment","version":"1.0","type":"link"}