The simpleABI-Q is a Doppler-Free Rapid PAD Screening PVR System used to rule PAD in or out and identify patients who need further evaluation, in one to two minutes. It uses pulse volume recording to deliver quick, repeatable vascular assessments, and it is built for speed, simplicity and staff efficiency — virtually any trained team member can run the test, with no Doppler experience required. Rather than diagnostic confirmation, this system focuses on rapid detection. In 1-2 minutes the system produces the ABI-Q report with a PVR waveform and ABI-Q values with guidance on if further evaluation is needed.
Best for
High-volume screening environments, diabetic foot clinics, and practices needing fast, staff-driven PAD assessments without Doppler expertise.
Screen first, confirm with Doppler
The simpleABI-Q is not a replacement for diagnostic ABI testing — it is the first step. Use it to screen broadly and quickly, then refer abnormal or borderline results for Doppler-based confirmation or purchase a simpleABI Automated Cuff-Link System, which performs the continuous-wave Doppler ankle brachial index recognized by the AHA and ACC as the gold standard for PAD diagnosis.
Why PVR-based screening?
Pulse volume recording evaluates blood flow by measuring volume changes in the limb rather than arterial pressure, so it works in patients with calcified arteries — common in diabetes — without needing a Doppler signal. Results are consistent and operator-independent, and test times are fast enough for high patient throughput. It is especially valuable in diabetic, podiatry and primary care settings.
When to choose a Cuff-Link system instead
Choose a simpleABI Automated Cuff-Link System rather than this system if you need to:
- Confirm a diagnosis rather than screen for one, with the gold-standard Doppler ankle brachial index.
- Measure toe brachial index with a PPG probe, for patients whose ankle vessels are calcified and an ankle pressure cannot be obtained.
- Localize the obstruction to a limb segment with three cuff or four cuff segmental studies, rather than only establishing that disease is present.
- Run Doppler exercise or treadmill stress studies, which this system does not perform.
- Automate cuff selection and inflation across several levels of the limb.
Software and reports
The software calculates indices automatically and stores each exam with a timestamp. Your practice logo and contact details print on the report, and physicians, operators, interpreters and ICD-10 codes sit on drop-down menus.
Reports save as PDF, TIFF, CSV, BMP or JPG, or print on any standard printer.
Seamless EMR integration — reports can be printed on any standard printer or saved as PDF/TIFF files for easy attachment to EMR patient records. Interested in DICOM connectivity? Call us at 800-675-1202 or email info@morningsidemedical.com for more information.
Accessories and supplies
Replacement cuffs, ultrasound gel and carry bags are listed in our ABI supplies collection.
- Doppler-free operation — no vascular training required
- Exam completes in one to two minutes
- Pulse volume recording waveform analysis
- Effective where arteries are calcified or incompressible
- Automatic index calculation and timestamped exam storage
- Push-button operation with a simple staff workflow
- Portable and compact for testing in any room
- Designed and manufactured in the United States, near Denver, Colorado
- simpleABI-Q laptop with Windows 11, 11.6 inch screen, 4 GB memory, 64 GB storage and a 6-hour battery, with the simpleABI-Q software already loaded
- simpleABI-Q software with automatic calculation and report generation
- PVR hardware for vascular waveform capture
- Two 10 cm EZ-Clean Vasocuffs
- Carry bag
- User manual and quick reference guides
A roll stand with a five-legged anti-tip base is available as an add-on for this product.
What happens if it breaks?
Manufacturer’s warranty: Every simpleABI system carries a comprehensive 2-year warranty covering all parts and labor.
Newman Medical also extends a 60-day satisfaction guarantee.
Morningside Medical Equipment General Refund Policy: There is a 30-day Return Policy (from the date of delivery) for all supplies and products purchased through our online store. These items must be unopened, unused, and in the original manufacturer packaging. Unfortunately, no returns will be accepted if used or damaged, or after the 30-day period. Customers are responsible for all shipping charges associated with the return. Initial shipping charges will not be refunded, and a 15%-20% restocking fee could be applied depending on the product.
See our terms and conditions for more information: www.morningsidemedicalequipment.com/terms-and-conditions
| Physical | |
|---|---|
| Weight | 2.75 kg (6 pounds) |
| Shipping weight | 6 lb |
| Shipping carton | 18 x 12 x 6 inches |
| Power | |
| System battery life | 10 hours |
| Computer battery life | 6 hours |
| Operating environment | |
| Temperature | 10 to 40 °C (50 to 104 °F) |
| Relative humidity | 30% to 75% |
| Transport and storage | |
| Temperature | -20 to 50 °C (-4 to 122 °F) |
| Relative humidity | 5% to 90%, non-condensing |
| Compliance | |
| Level of protection | Type B applied part, Class II equipment |
| Design standards | IEC 60601-1, IEC 60601-2 |
| Included computer | |
| Operating system | Windows 11 |
| Screen | 11.6 inch diagonal |
| Memory | 4 GB |
| Storage | 64 GB |
| Origin | |
| Country of manufacture | United States |